Two Fuels.
Easy Starts.
Meet the ERAYAK 4500PDE dual-fuel inverter generator. Choose gasoline or propane, enjoy convenient electric starting with recoil backup, and power compatible RV appliances, camping equipment and selected household essentials. Automatic propane-to-gasoline switchover provides additional operating flexibility.
Flexible Fuel. Effortless Power.
Gasoline and propane flexibility meets convenient electric starting in a portable 120V inverter generator.
Gasoline + Propane
Two fuel choices for travel, camping and portable backup. No natural-gas capability.
Electric Start
Convenient electric starting makes routine operation easier. Follow the proper starting sequence.
Recoil Backup
A manual pull-start option provides a second starting method when electric starting is unavailable.
Automatic Fuel Switchover
Designed to transition from propane to gasoline when propane pressure becomes insufficient.
Inverter Output
Inverter technology delivers power suitable for many compatible electronics and appliances.
ECO Mode
Adjusts engine operation according to electrical demand during lighter-load use.
Your Portable Power Hub.
A 30A locking receptacle, dual 20A household outlets and a compatible RV adapter provide practical connections for 120V equipment.
120V · 30A L5-30R
One 120V 30A locking outlet for compatible electrical equipment and 30A RV connections using the appropriate adapter.
Gasoline: Up to 3,500W running
Propane: Up to 3,150W running
Subject to the 30A receptacle and breaker limits.
Dual 120V · 20A Outlets
Two household-style outlets for compatible appliances, portable electronics, camping equipment and tools.
20A Circuit: 2,400W theoretical at 120V
Observe applicable breaker, shared circuit and total generator limits.
30A RV Adapter
A compatible L5-30P to TT-30R adapter allows a standard 30A RV power cord to connect to the generator's L5-30R outlet.
Voltage: 120V only
An adapter does not increase generator power or provide 240V.
Power Changes with Your Fuel.
Choose gasoline or propane based on your operating needs, then plan for the different running and peak ratings.
Gasoline Running Power
Up to 3,500W of rated output, with up to 4,500W temporary peak output for compatible starting requirements.
Propane Running Power
Up to 3,150W of rated output, with up to 4,050W temporary peak output. Connected loads must fit propane's lower power rating.
120V RV Connection
The L5-30R receptacle has a 30A rating at 120V. Actual continuous output remains limited to the selected fuel's generator rating.
The 4500PDE is designed to transition from propane to gasoline when propane pressure falls below its operating requirement, provided that usable gasoline is available in the tank and the system's required conditions are met. Monitor your fuel supply and connected electrical loads.
Important: 4,500W gasoline peak and 4,050W propane peak are temporary ratings, not continuous power. Individual outlet ratings do not increase total generator output. The generator's available capacity is shared across its receptacles. Check motor starting surge, running power and the selected fuel before adding electrical loads.
Easy Starts.
More Freedom.
Portable dual-fuel performance and convenient electric starting for RV camping, outdoor activities, electronic devices and selected 120V household backup needs.
RV Camping
Compatible 30A RV setups
Camping
Lighting and outdoor comforts
Home Essentials
Selected 120V backup loads
Outdoor Events
Portable power and lighting
Electronics
TVs, laptops and charging
Plan Your Power.
Explore 10 common appliances ranked from higher to lower estimated peak or maximum input wattage. Check both running power and startup demand. Available output is lower on propane than on gasoline.
Power Planning Note: All wattages are illustrative examples, not tested specifications for particular appliance models. Peak values for motor-driven equipment refer to estimated starting demand; maximum values for heating and lighting equipment refer to estimated input power. Actual starting requirements can vary significantly. Some RV air conditioners may need a compatible soft starter. The ERAYAK 4500PDE provides 4,500W peak / 3,500W running on gasoline and 4,050W peak / 3,150W running on propane. Equipment with starting demand near these peak limits may not start reliably, especially with other loads already connected. Check each appliance's actual voltage, running watts, startup requirements, outlet ratings and total connected load before use.
Convenient Starts. Flexible Fuel.
Electric Start + Recoil Backup
Enjoy convenient electric starting with a manual recoil option as an alternative. The 4500PDE is the electric-start model of the 4500PD series.
Gasoline Runtime
With the 2.25 gal gasoline tank, published runtime is up to 12 hours at 25% load or 8 hours at 50% load under specified test conditions.
Propane Runtime
With a 20 lb propane tank, published runtime is up to 12 hours at 25% load, 8 hours at 50% load or 5 hours at full load.
ECO Mode
ECO mode adjusts engine speed to changing power demand. Disable ECO when appropriate for appliances with high motor starting requirements.
Engine Maintenance
Engine oil capacity: 0.6L / 600mL. Check oil before use and follow the manual's recommended oil, filter and spark plug maintenance schedule.
Electrical Protection
Low-oil and overload protection help protect the generator. The built-in parallel connection interface must be used only with compatible approved equipment.
Runtime Test Conditions: Published figures are based on tests at approximately 77°F (25°C). Actual runtime varies with connected load, fuel quality, altitude, temperature and operating conditions. Noise rating: 58 dBA at 23 ft (7 m) under the manufacturer's stated measurement conditions.
Connect Your RV the Right Way.
A compatible L5-30P to TT-30R adapter allows a standard 30A RV power cord to connect to the generator's 120V L5-30R locking outlet.
Prepare Your Fuel
Choose gasoline or propane and set up the selected fuel according to the owner's manual. If relying on automatic propane-to-gasoline switchover, ensure usable gasoline is available.
Connect a Compatible Adapter
With the generator stopped and RV loads disconnected, connect a correctly rated L5-30P to TT-30R adapter to the L5-30R receptacle. Attach the compatible 30A RV power cord.
Start & Manage Loads
Start the generator using electric start or the recoil backup method. Add RV electrical loads gradually after output stabilizes. Stay within the selected fuel's continuous power rating.
RV Compatibility: An L5-30P to TT-30R adapter is for compatible 120V 30A RV connections. It does not create 240V output, provide full 50A RV service or increase the generator's wattage. RV air conditioner compatibility depends on compressor startup and total connected demand.
Operate the generator outdoors only, at least 20 ft from doors, windows and vents, with exhaust directed away from occupied buildings. Never run inside an RV, tent, home, garage, shed or other enclosed or partially enclosed area. Use functioning carbon monoxide alarms. Keep the generator dry and avoid rain, standing water and flooding. Install propane hoses and regulators according to the manual. Check connections for leaks before starting and keep propane tanks properly positioned and secured. Never refuel gasoline while the engine is running or hot. Use appropriately rated electrical cords and connections, disconnect loads before shutdown and follow all manufacturer's safety instructions.




















































